News
Product No:HY-230
Brand:HONG YE JIE
Product Usage:High polymer dampproof plugging agent it is a new environment-friendly moisture-proof sealant specially used for distribution network outdoor ring main unit box type transformer cable branch box distribution network control cabinet and substation outdoor terminal box. The polymer moisture-proof plugging agent adopts high polymer mixing technology and high active chemical substance formula with low viscosity good fluidity self leveling easy penetration no deformation no deterioration No cracking. Fully seal the gap at the bottom of electrical equipment; It can withstand natural temperature freeze-thaw cycle and various harsh environments and effectively prevent small animals from entering the closed cabinet from underground. It is an excellent scheme for safe operation of power grid electrical equipment and moisture-proof plugging operation.
INTRODUCTION
The role of ring network cabinet is to protect the transformer and limit the short circuit current, to prevent the transformer from suffering from sudden short circuit fault current, and to quickly cut off the short circuit fault within 10ms to prevent transformer damage caused by the pressure rise caused by internal arc, and to make the transformer more reliable and reasonable protection. The ring network cabinet plays an indispensable role in the power system, So once the ring network cabinet is damp, it has great security risks to the operation of the power grid. The principle of sealing the ring network cabinet is to block the inlet and outlet, holes and door joints of each ring network cabinet, to prevent the entry of wet air, and prevent small animals from entering the enclosure from the underground, thus reducing the safety hazards; It can realize the airtight and moisture-proof inside the cabinet, and provide strong protective barrier for the production and operation equipment.
Once the ring network cabinet is invaded by humid air, it is easy to condense in the ring cabinet in a moment. Condensate reaches a certain leve, the degree will drop on the components in the cabinet, causing creepage, short circuit, etc., and condensation and corrosion will be formed in the cabinet. If the switch is light, the switch will be touched by mistake, and serious fire may also cause safety accidents. At present, there are not a few accidents caused by the tide of the ring network cabinet in China. It is very important to prevent moisture from blocking the ring network cabinet.
It is common for the power industry to fail due to the tide. Humidity has a certain degree of damage to electrical equipment, which will affect the safe operation of power equipment, so it is imperative to do well in the work of moisture-proof and dehumidification.
APPLICATION
High polymer dampproof plugging agent, it is a new environment-friendly moisture-proof sealant specially used for distribution network outdoor ring main unit, box type transformer, cable branch box, distribution network control cabinet and substation outdoor terminal box. The polymer moisture-proof plugging agent adopts high polymer mixing technology and high active chemical substance formula, with low viscosity, good fluidity, self leveling, easy penetration, no deformation, no deterioration No cracking. Fully seal the gap at the bottom of electrical equipment; It can withstand natural temperature freeze-thaw cycle and various harsh environments, and effectively prevent small animals from entering the closed cabinet from underground. It is an excellent scheme for safe operation of power grid electrical equipment and moisture-proof plugging operation.
ADVANTAGES
High safety: waterproof, moisture-proof, dust-proof, prevent small animal invasion, fire retardant
Simple operation: simple construction, single person operation, without auxiliary (electricity, fire and water, etc.), the surface can be dried quickly in 30 minutes
Good fluidity: fully flow on the sealing surface before curing and automatically level, without manual grinding
Resistant to all kinds of harsh environment: anti-corrosion, can withstand all kinds of harsh environment
Tight adhesion: closely combined with cable sheath and surrounding building structure, no corrosion reaction
Solid structure: solid molecular closed cell matrix structure, toughness, light weight after molding, will not break or fall
Lasting effect: no deformation, deterioration and cracking after curing, and the service life is more than or equal to 10 years
Convenient construction: it can be used on the suspended floor or directly on the floor. It is an ideal choice for the safety protection of electrical equipment, and the secondary opening is simple and convenient.
Polymer dampproof plugging self leveling material: the plugging agent flows into the target area fully and automatically on the sealing surface before curing, so it does not need to be smoothed, and the construction is simple. It can quickly and conveniently flow through the complex through pipes or cables and other cabinets, fill the irregular surface, and finally form a solid shape.
Component properties: two in one polymer materials with high active chemicals.
Curing property: forming a solid closed cell matrix after solidification.
Chemical resistance: it can prevent the chemical corrosion of gasoline, petroleum, dilute acid and alkali, base and most unsaturated hydrocarbons.
Field application: fully mix the solution, slowly pour the mixed solution on the target surface, and the field application can be completed after the surface of the mixed solution is dry.
Re repair: new cable or secondary construction can be carried out with woodworking knife. After completion, pour some moisture-proof plugging agent into the opening to seal the area. After the newly added cables or pipelines are installed, some additional moisture-proof plugging agents shall be used You can seal the area again.
Product Usage:HY-230 high polymer dampproof plugging agent is well known as a perfect potting material encapsulating material as well as sealing material it's a perfect plugging agent for new energy vehicle charging pile distribution network outdoor ring network cabinet box type transformer cable branch box distribution network control cabinet and substation outdoor terminal box mechanism operation box electric knife switch box high and low voltage switch cabinet junction control unit cabinet distribution room etc.
INTRODUCTION
It is common for the power industry to cause troubles due to the damp.
Humidity has a certain degree of damage to electrical equipment, which will affect the safe operation of power equipment, so it is imperative to do well in the work of moisture-proof and dehumidification.
APPLICATION
HY-230 high polymer dampproof plugging agent is well known as a perfect potting material, encapsulating material as well as sealing material, it's a perfect plugging agent for new energy vehicle charging pile, distribution network outdoor ring network cabinet, box type transformer, cable branch box, distribution network control cabinet and substation outdoor terminal box, mechanism operation box, electric knife switch box, high and low voltage switch cabinet, junction control unit cabinet, distribution room, etc.
WHY USE HIGH POLYMER PLUGGING AGENT FOR ELECTRIC CABINET
1. The phenomenon of damp - Plugging.
Ring network cabinet is used to protect the transformer and limit the short circuit current, to prevent the transformer from the sudden short circuit fault current, and to quickly cut off the short circuit fault within 10ms, so as to prevent the transformer from damage caused by the pressure rise caused by internal arc, so that the transformer can be protected more reliably and reasonably, ring network cabinet plays an indispensable role in power system, so once the ring cabinet is damp, it has great security risks to the operation of the power grid.
The principle of sealing the ring network cabinet is to sealing the inlet and outlet, holes and door joints of each ring network cabinet, to prevent the entry of wet air, and prevent small animals from entering the enclosure from the underground, thus reducing the safety hazards; It can realize the airtight and moisture-proof inside the cabinet, and provide strong protective barrier for the production and operation equipment.
Once the ring network cabinet is invaded by humid air, it is easy to condense in the ring cabinet in a moment. If the condensate reaches a certain level, it will drip onto the components in the cabinet, causing creepage, short circuit, etc. and condensation and corrosion will be formed in the cabinet. If it is light, the switch will touch by mistake, and if it is heavy, the fire will break out and may also cause safety accidents. At present, there are not a few accidents caused by the tide of the ring network cabinet in China. It is very important to prevent moisture from potting the ring network cabinet.
2. The moisture-proof sealing materials used in the existing traditional cable trenches are mostly inorganic blocking materials or fire-proof bags, which are of poor stability. Once they are eroded by moisture or washed by rain, they will be affected by moisture and deformation, which will greatly reduce the effective performance of fire retardant, which is difficult to achieve the normal effect of fire-retardant and fire prevention and moisture-proof! And if there is a fire inside the cable trench, the consequences are unthinkable!
3. The fire-proof mud was used to block the bottom of the cabinet and cable mouth in the past. After more than one year of operation of the cable junction box, the fire mud at the bottom of the cabinet appeared oil flow, cracking, collapse, aging and falling off phenomenon, which had poor sealing effect and lost the function of moisture-proof sealing, which made the cabinet easy to have condensation and safety hazards brought by small animals, It is seriously threatening the operation safety of power equipment and cannot meet the requirements of moisture-proof sealing, so it is necessary to re block, and the disadvantages such as high maintenance cost of fire-proof mud and short durability time are gradually exposed. After long-term use, fire mud has many disadvantages, such as heavy pollution, easy to destroy, collapse, easy to dry and crack, easy to be polluted.
Product Usage:HY-230 polymer moisture-proof plugging agent which is mainly used in electric power. It is specially used in distribution network outer ring network cabinet box type transformer cable branch box distribution network control cabinet and substation outdoor terminal box mechanism operation box electric knife switch box high and low voltage switch cabinet central control unit cabinet etc.
INTRODUCTION
Many electrical equipment failures are caused by moisture and moisture. How to prevent moisture and dehumidification of electrical equipment has always been the concern of power operation and maintenance personnel. In the humid environment, indoor power facilities are facing more and more obvious threats, which have a great impact on the safe operation of electrical equipment. In electrical engineering, when the relative humidity is greater than 80% RH, it is called high humidity; high humidity is the main cause of electrical equipment accidents.
If you want to be able to prevent moisture and dehumidification, you need to block the immersion of moisture and humid air. How can you do this? You can block the bottom of the cabinet with high polymer moisture before it is put into use or when it is transformed, and cut off the path of hot and cold air circulation. On the one hand, you can avoid moisture, and if there is no moisture, it will not condense naturally. On the other hand, you can prevent small animals from entering Damage to electrical equipment.
APPLICATION
HY-230 polymer moisture-proof plugging agent is mainly used in electric power. It is specially used in distribution network outer ring network cabinet, box type transformer, cable branch box, distribution network control cabinet and substation outdoor terminal box, mechanism operation box, electric knife switch box, high and low voltage switch cabinet, central control unit cabinet, etc.
ADVANTAGES
* Flame retardant UL: 94V-0 [ E354635 ]
* High safety: waterproof, moisture-proof, dust-proof, prevent small animal invasion, fire retardant
* Simple operation: simple construction, single person operation, no auxiliary (electricity, fire and water, etc.)
* Good fluidity: fully flow on the sealing surface and automatically level before curing
* Resistant to all kinds of harsh environment: anti-corrosion, can withstand all kinds of harsh environment
* Tight adhesion: closely combined with cable sheath and surrounding building structure, no corrosion reaction
* Solid structure: solid molecular closed cell matrix structure, toughness, light weight after molding, will not break or fall
* Long effect: no deformation, deterioration and cracking after curing, and the service life is more than or equal to 10 years
* Convenient construction: it can be used on the suspended floor or directly on the floor. It is an ideal choice for the safety protection of electrical equipment, and the secondary opening is simple and convenient
OPERATION PROCESS
1. Before use, first mix component a evenly, which can make the colloid fluidity better than that of the long standing and direct use, and also make the settled gray pigment mix evenly; then shake component B well, which can make the adhesive component of agent B more uniform.
2. When mixing, the weight ratio of component A: component B = 10:1 should be observed.
3. 25 degrees of room temperature curing products, after perfusion in room temperature curing, basic curing into the next process, deep curing needs 12 hours.
Ambient temperature and humidity have A great impact on curing, such as environmental humidity is too low, easy to affect the bonding performance of the material, can consider adding 1/1000 of water in proportion to A component, or placing A humidifier in the environment.It should be noted that when water is added, the operational time of the material will be shortened accordingly.
Product Usage:Actually many electrical equipment failures are caused by moisture and moisture. How to prevent moisture and dehumidification of electrical equipment has always been the concern of power operation and maintenance personnel.
INTRODUCTION
Actually many electrical equipment failures are caused by moisture and water. How to prevent moisture and dehumidification of electrical equipment has always been the concern of power operation and maintenance personnel.
Think about the environmental conditions of transformer, have to be exposed to the sun, wind, rain and getting wet, insects, ants and mouse go inside the transformer box always too which hurt the transformer box.
ADVANTAGES
HY-230 silicone rubber can solve above problems with these advantages: Flame retardant UL: 94V-0 [ E354635 ], waterproof, moisture-proof, dust-proof, prevent small animal invasion, fire retardant, and resistant to all kinds of harsh environment: anti-corrosion, can withstand all kinds of harsh environment.
HY-230 is at top in this field which is the most widely used in China, we sold hundred of tons of HY-230 at 2020, mainly to goverments' projects, as a sealing and potting material for outdoor substation box like pictures.
SITE CONSTRUCTION
NATIONAL HIGH TECH ENTERPRISE ▏STANDARDIZED PRODUCTION ▏ONE STOP INTEGRATED SOLUTION PROVIDER
Mix ratio: two in one polymer material with high active chemicals, organic silicon compound. The ratio of A and B is 10:1.
Stir evenly: mix a and B for about 2-3 minutes, subject to uniform stirring.
Pour into the cabinet: after mixing, the plugging agent still has good fluidity within the operation time range, automatically flows into the target area, does not need to be smoothed, and the construction is simple. It can quickly and conveniently flow through the complex through pipes or cables and other cabinets, fill the irregular surface, and finally form a solid shape.
Curing performance: after the plugging agent is stirred evenly, there is about 20 minutes of operation time. After the surface of the AB mixture is dry, the field application can be completed, and a solid closed cell matrix can be formed in 1-2 hours.
Chemical resistance: it can prevent the chemical corrosion of base from gasoline, petroleum, dilute acid and alkali, most unsaturated hydrocarbons.
Re repair: new cable or secondary construction can be carried out with woodworking knife. After completion, pour some moisture-proof plugging agent into the opening to seal the area. After the new cable or pipeline is installed, the area can be re sealed by using some moisture-proof plugging agent, which is convenient for repair.
Brand:HONG YE JIE
Product Usage:Anti-condensation sealing material equipment testing in the power industry can see the plugging situation through the following three points. Anti-Condensation Sealing Material UD-HPS is sealing of waterproof small animal proof flame retardant thermal insulation and anti condensation at the bottom of the inlet and outlet cabinets of high and low voltage switchgear box type substation cable branch box ring network cabinet American box type transformer terminal box wind box transformer photovoltaic box transformer special box transformer for high speed railway and other power equipment cable rooms.
Anti-condensation sealing material equipment testing in the power industry can see the plugging situation through the following three points
1. Look at the smoke
The smoke emitted by electrical equipment during operation can be divided into white, yellow and black. White smoke is the steam generated by damp electrical equipment after heating. In fact, it is not smoke.
If black smoke is emitted, the possibility of electrical equipment damage is great, which means that the insulation of electrical equipment is burned out.
2. Look at the coil
If there is a sudden change in the color of one turn of the coil, it is necessary to consider whether there is moisture and corrosive substances around it. If the insulating material wrapped on the cable and wire joint changes color, cracks and falls off, it must be caused by heating caused by poor conductor contact.
3. Look at the temperature
During peak winter, in order to accurately grasp the operation level of distribution network equipment, it is required to hold infrared thermometer and hygrometer to measure the load of lines of different levels, and do a good job in data collection and analysis during high load period.
Of course, there are many other ways and means, and the above points clearly show that the cause of the fault is related to moisture and moisture in the cabinet.
Construction scheme of anti-condensation sealing material
(1) Clean the working face, clean the inner wall of the pipe with a steel wire brush, roughen the inner wall of the pipe, and clean the sundries adhered to the cable with sandpaper.
(2) Fill the gaps around the blocking plate with fireproof materials to ensure tightness and flatness, and the blocking plate shall be horizontal.
(3) Mix the ingredients according to the specified proportion, mix the components a and B of polymer plugging agent evenly, stir for more than five minutes, and pour them into the plate body after stirring evenly.
Construction materials
Foaming BBS anti condensation plugging agent or non foaming self leveling plugging agent can be used.
Application scope
Anti-Condensation Sealing Material UD-HPS is sealing of waterproof, small animal proof, flame retardant, thermal insulation and anti condensation at the bottom of the inlet and outlet cabinets of high and low voltage switchgear, box type substation, cable branch box, ring network cabinet, American box type transformer, terminal box, wind box transformer, photovoltaic box transformer, special box transformer for high speed railway and other power equipment cable rooms.
Search from here