Ms. zhou

What can I do for you?

Ms. zhou

What can I do for you?

Home> Products> Liquid Tank Adhesive> HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal
HVAC AHU Air Handling Unit Filter Gel Seal

HVAC AHU Air Handling Unit Filter Gel Seal

$12-20 /Kilogram

Payment Type:T/T,Paypal
Incoterm:FOB,Express Delivery,CIF,EXW,DDP
Min. Order:1 Kilogram
Transportation:Ocean,Land,Express,Air
Port:SHENZHEN
Packaging & Delivery
Selling Units : Kilogram
Package Type : 1/5/20/25/200KG
Picture Example :

The file is encrypted. Please fill in the following information to continue accessing it

Product Description

PRODUCT OVERVIEW:

Hong Ye HY-9400 is a premium two-component addition-cure platinum catalyzed blue jelly gel specifically engineered for sealing bag-in-frame and gel-channel HEPA filters in air handling units (AHU) serving commercial and industrial HVAC systems. With a buttery soft consistency measured at a penetration of 200 plus or minus 30 (0.1mm) and a durably tacky surface, HY-9400 delivers reliable long-life sealing and protection that outlasts conventional gaskets, foams and caulks by a wide margin. The product is mixed 1:1 by weight, self-levels after pouring, cures at room temperature within 4 to 6 hours, and requires no vacuum degassing, making it a straightforward high-performance gel to deploy on production lines worldwide. This high-tack variant offers strong self-healing: after parts are disassembled and reinserted the gel re-seals quickly to maintain a durable zero-leakage seal. It is formulated to meet the specific demands of the AHU filter frame gel track, tolerating years of humid recirculated air, cooling-coil condensation and seasonal temperature changes with a durable airtight seal. Backed by Hong Ye's nearly 20 years of silicone manufacturing expertise and supplied to customers in over 60 countries, HY-9400 combines the performance of premium imported gels with the cost efficiency, short lead time and responsive technical support of a Chinese manufacturer. Whether you are running a first sample trial or ramping to full production, Hong Ye delivers consistent batch-to-batch quality, comprehensive documentation and application engineering support from first sample through full production.

Liquid tank adhesive

KEY FEATURES:

• High tack with strong self-healing performance, re-sealing quickly after disassembly and reinsertion for stringent zero-leakage requirements.

• Excellent electrical insulation with dielectric strength above 20 kV/mm

• Repairable and reworkable: old gel can be topped up with fresh gel without full removal

• No VOC emissions during or after cure, suitable for enclosed cleanroom and medical environments

• Can be heat-cured at 60-80C for 30-60 minutes to shorten demolding time in mass production

• Resistant to ozone, UV, moisture, salt spray and common cleanroom cleaning agents

• 1:1 mix ratio by weight, easy to meter with manual or automated dispensing equipment

• Compatible with automated meter-mix dispensing equipment for high-volume production lines

• Third-party test reports including RoHS, REACH, FDA and LFGB available on request

• Self-leveling after pouring, no vacuum degassing required, saving process time and equipment

• Wide service temperature range from minus 60C to 200C with stable flexibility and tack

• Low exotherm and low shrinkage during cure, avoiding stress on delicate components and seals

 

TECHNICAL PARAMETERS:

Model

Color

Viscosity

(mPa·s)

Operation

Time (min)

Cure Time

(h)

Penetration

(0.1mm)

Tack

Mix Ratio

Density

(g/cm³)

HY-9400

Blue

1200+/-300

20-40

4-6

200+/-30

High

1:1

0.98

 

DETAILED APPLICATION SCENARIOS:

Large commercial and industrial HVAC systems use gel-seal HEPA and high-efficiency filters in air handling units serving hospitals, airports, factories and clean manufacturing spaces. Hong Ye HY-9400 is poured into the gel track of the AHU filter frame, where the filter knife-edge rests in the soft blue gel to form an airtight, leak-free seal. This eliminates the bypass air that sneaks around conventional gaskets as they age, helping the system maintain rated airflow and filtration efficiency and protecting occupants and processes from airborne contamination.

AHU environments are defined by long service life and cycling conditions: humid return air, condensation near cooling coils, seasonal heating and cooling swings, and occasional wash-down. HY-9400 maintains its softness and seal through these changes, resisting the hardening, shrinking and gasket set that cause air leakage over time. When building maintenance replaces filters on a planned schedule, the tacky self-healing gel re-seats around each new filter without re-pouring, so the service crew changes filters quickly while the AHU keeps delivering its designed protection level.

The blue pigment makes it easy for installing contractors to verify the gel channel is full and the filters fully seated across large multi-filter banks, and the low-odor, zero-VOC cure suits occupied and healthcare buildings. Hong Ye provides cost-effective material for large HVAC projects, straightforward 1:1 mixing compatible with manual or automated dispensing, and complete export documentation including COA, RoHS and REACH reports to support mechanical contractor submittals and building commissioning.

 

APPLICATION & OPERATING INSTRUCTIONS:

Step 1 Surface preparation: Clean the gel channel or cavity with a dry lint-free cloth. Remove all oil, water, rust, latex residue and old cured silicone fragments. For new housings, wipe with isopropyl alcohol and allow to fully dry.

Step 2 Component B preparation: Before each use, stir component B thoroughly for at least 2 minutes. The pigment and catalyst can settle during storage; incomplete stirring causes color variation and soft or uncured spots.

Step 3 Weighing and mixing: Weigh A and B at exactly 1:1 by weight using a calibrated scale. Pour into a clean mixing container and stir slowly for 3 to 5 minutes, scraping the sides and bottom regularly. Avoid fast stirring which introduces bubbles.

Step 4 Pouring: Pour the mixed gel slowly along one end of the channel or cavity and allow it to self-level. Do not pour from a height to avoid air entrapment. For long channels or large cavities, pour in sections.

Step 5 Curing: Allow 4 to 6 hours at 25C before handling or assembly. Full physical properties develop after 24 hours. No vacuum degassing is required. Heat-curing at 60-80C for 30-60 minutes shortens the cycle for mass production.

Step 6 Contamination prevention: Use polyethylene, nylon or nitrile gloves. Never use natural rubber latex gloves. Avoid contact with sulfur-containing materials, amines, phosphorus compounds, tin-cured silicone and PVC, as these can inhibit the platinum catalyst and prevent cure.

After the gel has fully cured, the sealed channel, cavity or enclosure is ready for service; no vacuum degassing, post-cure or special equipment is required for standard room-temperature installations. During the first 24 hours, protect freshly poured gel from dust, dripping water and contact with uncured tin-cured silicone or latex. For reliable results, first-time users are encouraged to run a small trial on a spare channel or sample cavity to confirm depth, coverage and handling time before scaling to full production. Hong Ye application engineers can review your housing or component drawings, recommend pour depth and gel grade, and provide a short mixing-and-pouring video or live online guidance for the first batch, helping line operators establish a stable, repeatable pouring process.

 

PACKAGING:

Standard packaging options include 1kg trial kits (500g A plus 500g B), 5kg kits, 20kg pails, 25kg pails and 200kg drums. Components A and B are supplied in separate containers within each kit, and both are clearly marked to avoid mix-up. Custom packaging, private labeling and kit configurations are available for orders above 200kg, and mixed-A/B cartridges can be prepared for cartridge dispensing. All kits are clearly labeled with batch number, manufacture date, expiry date and safety information. For export orders, packaging meets sea and air freight requirements with English labels, SDS and COA documents included. Trial orders typically ship within 1 to 3 working days, and volume orders within 7 to 10 working days depending on quantity and certification requirements.

package4

 

QUALITY ASSURANCE & SUPPORT:

Hong Ye has manufactured addition-cure silicone gels in its own ISO 9001 certified facilities since 2005 and supplies customers in more than 60 countries across cleanroom, filtration, electronics and consumer product industries. Every batch of HY-9 series jelly gel is tested for viscosity, mix ratio, cure time, penetration, color and tack before release, and a Certificate of Analysis showing actual measured values ships with every order so incoming-quality teams can verify consistency on receipt. Raw-material inspection, in-process mixing control and finished-product testing form a three-stage quality system that keeps batch-to-batch variation tight for automated production. Standard grades are supported by RoHS 2.0 and REACH SVHC test reports, skin-contact and food-contact grades can be supplied with FDA 21 CFR 177.2600 and LFGB Section 30/31 reports, and ISO 10993 biocompatibility testing can be arranged on request. Our application engineers provide grade selection, sample evaluation, channel or cavity design review, on-site or video pouring guidance and after-sales follow-up, and TDS technical data sheets, SDS safety data sheets and test reports are available before order to support customer qualification, audit and tender processes. Hong Ye welcomes trial sample requests and supports customers from first sample through full volume production.

 

FREQUENTLY ASKED QUESTIONS:

Q: How long does the gel take to cure and can I speed it up?

A: At 25C the gel reaches touch-dry in 4 to 6 hours and full properties after 24 hours. For mass production, heat-curing at 60 to 80C reduces demolding time to 30 to 60 minutes. Do not exceed 100C as it may cause discoloration or surface defects. Low temperatures below 15C will significantly slow the cure.

Q: Will the gel self-heal after a component is removed and reinserted?

A: Yes. The cured gel remains durably tacky and soft. When a knife edge, flange or insert is lifted, the gel temporarily separates; when reinserted, it flows back around the part within minutes, restoring the airtight or watertight seal. This self-healing property is a key advantage over compressed gaskets and foams during periodic maintenance.

Q: What is the mix ratio and how do I avoid curing problems?

A: Mix components A and B at exactly 1:1 by weight using a calibrated scale, then stir slowly for 3 to 5 minutes while scraping the container walls and bottom. Use nitrile, polyethylene or nylon gloves, never natural latex. Keep the material away from sulfur, amines, phosphorus, tin-cured silicone and PVC, which can inhibit the platinum catalyst and leave sticky or uncured spots.

Q: Can old gel in a tank, channel or housing be topped up or repaired?

A: Yes. If the existing gel is still clean, soft and tacky, wipe the surface with a dry cloth and pour fresh gel on top; the fresh addition-cure gel bonds chemically to the clean cured gel. If the old gel has hardened, dried out, yellowed or become contaminated, remove it completely, clean the channel and refill.

Q: What certifications and test reports are available for export or regulated industries?

A: Standard grades ship with a Certificate of Analysis and RoHS 2.0 and REACH SVHC reports. Skin-contact and food-contact grades can be supplied with FDA 21 CFR 177.2600 and LFGB Section 30/31 reports, and ISO 10993 biocompatibility testing on request; flame-retardant grades meet UL94 V-0. TDS, SDS and test reports are provided before order to support customer qualification and tender processes.

Q: How do I place a trial order and choose the right grade for my application?

A: Most customers start with a 1kg or 5kg trial kit to validate pour depth, cure and sealing or potting performance on the actual part. Share your application, temperature and service environment with our sales engineer and we will recommend the blue high-tack, blue medium-tack or transparent grade that fits your conditions, along with pour-depth guidance and documentation. Trial orders ship within 1 to 3 working days, and once the grade is qualified we can support volume production with stable lead times, custom packaging and private labeling for orders above 200kg.

Q: Does condensation and high humidity in the AHU affect the gel seal?

A: No. The cured silicone gel is inherently water-resistant and does not swell, soften or wash out under the humid recirculated air and cooling-coil condensation typical of air handling units. It keeps its softness and tack through seasonal humidity and temperature swings. We recommend keeping the gel channel free of standing water during initial pour and cure; once fully cured, normal AHU condensation causes no problem.

Home> Products> Liquid Tank Adhesive> HVAC AHU Air Handling Unit Filter Gel Seal
  • Send Inquiry

Copyright © 2026 Shenzhen Hong Ye Jie Technology Co., Ltd All rights reserved. Privacy Policy

Send Inquiry
*
*

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send